Juniper WLA522 Guida di Installazione Pagina 19

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 35
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 18
Copyright © 2011, Juniper Networks, Inc. Installing an Indoor WLA522 19
Wireless LAN Access Point WLA522 and WLA522E Quick Start Guide Part Number: 530-042353 Rev.01
Figure 12: Step 6—Top View
Figure 13: Step 6—Bottom View
7. Pull the Cat 5 cable about 15 centimeters (about 6 inches) out of the hole in the ceiling tile and through the
port connector opening to create enough slack to insert the cable.
8. Insert the Cat 5 cable into the connector.
9. Install the Kensington lock, if you plan to use one.
a. Loop the Kensington lock cable around an object that cannot be moved or damaged by a person
pulling on the cable.
b. Insert the key into the Kensington lock.
c. Insert the Kensington lock into the security slot on the AP.
d. Rotate the key right or left to secure the lock to the AP.
e. Pull on the lock to verify that it is secured to the AP.
f. Remove the key.
T- bar
T-bar clamps
(attached
to T-bar)
Universal mounting
bracket
(Viewed from above ceiling tiles, looking down.)
Port connector
opening
T- b a r
Universal mounting bracketPort connector
opening